Maintenance Analysis Procedures (MAPS)
No action is required for an isolated event. However, if this event
persists, perform one of the following:
Relieve the congestion by adding parallel ISLs between the
directors or switches reporting the problem.
Increase the ISL link speed between the directors or switches
reporting the problem (from 1 Gbps to 2 or 10 Gbps).
Reroute Fibre Channel traffic by moving device connections to a
less-congested region of the fabric.
Did the corrective action solve the problem and relieve the reported
ISL congestion?
NO YES
The ISL appears operational. Exit MAP.
Contact the next level of support. Exit MAP.
22
A 142 event code occurs only if the optional OpenTrunking feature is
enabled. The event code indicates OpenTrunking firmware detected
an ISL with no transmission BB_Credit for a period of time that
exceeded the configured low BB_Credit threshold. This results in
downstream fabric congestion.
No action is required for an isolated event or if the reporting ISL
approaches 100% throughput. However, if this event persists, perform
one of the following:
Relieve the congestion by adding parallel ISLs between the
directors or switches reporting the problem.
Increase the ISL link speed between the directors or switches
reporting the problem (from 1 Gbps to 2 or 10 Gbps).
Reroute Fibre Channel traffic by moving device connections to a
less-congested region of the fabric.
Did the corrective action solve the problem and relieve the reported
low BB_Credit condition?
NO YES
The ISL appears operational. Exit MAP.
Contact the next level of support. Exit MAP.