MAP 0700: Fabric, ISL, and Segmented Port Problem Determination
3-119
Maintenance Analysis Procedures (MAPS)
23
A 150 event code indicates a zone merge failed during ISL
initialization. Either an incompatible zone set was detected or a
problem occurred during delivery of a zone merge frame. This event
code always precedes a 070 event code, and represents the reply of
an adjacent fabric element in response to a zone merge frame.
Obtain supplementary event data for each 150 event code.
a. At the Hardware View, click Logs and select Event Log. The
Event Log displays.
b. Examine the first 12 bytes (0 through 11) of event data.
c. Bytes 0 through 3 specify the E_Port number (00 through 23)
reporting the problem. Bytes 8 through 11 specify the failure
reason (Table 3-17).
24
A zone merge failed during ISL initialization. The following list
explains the reason:
Failure reason 01 - An invalid data length condition caused an
error in a zone merge frame.
Failure reason 08 - An invalid zone set format caused an error
in a zone merge frame.
Failure reason F0 - A retry limit reached condition caused an
error in a zone merge frame.
Table 3-17 Bytes 8 through 11 Failure Reasons and Actions
Bytes 8 - 11 Failure Reason Action
01 Invalid data length. Go to step 24.
08 Invalid zone set format. Go to step 24.
09 Invalid data. Go to step 25.
0A Cannot merge. Go to step 25.
F0 Retry limit reached. Go to step 24.
F1 Invalid response length. Go to step 24.
F2 Invalid response code. Go to step 24.