FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)
4
Obtaining Log Information
4-7
Repair Information
Figure 4-3 Intrepid 6064 Event Log
The log displays a history of director events, such as degraded
operation, FRU failures, FRU removals and replacements, port
problems, Fibre Channel link incidents, and management server-to-
director communication problems. The information is useful to
maintenance personnel for fault isolation and repair verification.
The log contains the following columns:
• Date/Time - The date and time the event occurred.
• Event - The three-digit event code associated with the event. See
Appendix B, Event Code Tables for an explanation of event codes.
• Description - A brief description of the event.
• Severity - The severity of the event (Informational, Minor, Major, or
Fatal).
• FRU-Position - An acronym representing the FRU type, followed
by a number representing the FRU chassis position. FRU
acronyms are:
— BKPLNE - backplane.
— CTP - control processor (CTP2) card.
— SBAR - serial crossbar (SBAR) card.
— UPM - universal port module (UPM) card.
— XPM - 10 Gbps port module (XPM) card.
— PM - port module (designation before a port module is
identified as an FPM, UPM, or XPM type)
— FAN - fan module.
— PWR - power supply.