FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)
4
4-8
Intrepid® 6064 Director Installation and Service Manual
Repair Information
The chassis (slot) position for a nonredundant FRU is 0. The
chassis positions for redundant FRUs are 0 and 1. The chassis
positions for port cards are 0 through 15 inclusive.
• Event Data - Up to 32 bytes of supplementary event data (if
available) in hexadecimal format. See Appendix B, Event Code
Ta b le s for an explanation of the supplementary event data.
Intrepid 6064
Hardware Log
To open the Intrepid 6064 Hardware Log, select the Hardware Log
option from the Logs menu at the Hardware View, Port List View, Node
List View, Performance View, or FRU List View. The log displays
(Figure 4-4).
Figure 4-4 Intrepid 6064 Hardware Log
The log displays a history of FRU removals and replacements
(insertions) for the director. The information is useful to maintenance
personnel for fault isolation and repair verification.
The log contains the following columns:
• Date/Time - The date and time the FRU was inserted or removed.
• FRU - An acronym representing the FRU type. FRU acronyms
are:
— BKPLNE - backplane.
— CTP - CTP2 card.
— SBAR - SBAR card.
— UPM - UPM card.
— XPM - XPM card.
— PM - port module
— FAN - fan module.
— PWR - power supply.