FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)

4
4-32
Intrepid® 6064 Director Installation and Service Manual
Repair Information
7. Click Next. The message Press START TEST to begin diagnostics
appears, and the Next button changes to a Start Test button.
8. Click Start Test. The test begins and:
a. The Start Test button changes to a Stop Test button.
— The message Port xx: TEST RUNNING appears, where xx is
the port number. If a port card is tested, the message appears
for all ports.
b. A red progress bar (indicating percent completion) travels
from left to right across the Completion Status field.
As a port is tested, the amber LED flashes (beacons) and the green
LED extinguishes (indicating the port is blocked).
NOTE: Click Stop Test at any time to abort the loopback test.
9. When the test completes, results appear as Port xx: Passed! or
Port xx: Failed! in the message area of the dialog box. If a port
fails the test, the amber LED for the port remains illuminated.
10. When finished, click Cancel to close the Port Diagnostics dialog
box.
11. Reset the port:
a. At the Hardware View, right-click the port graphic. A pop-up
menu appears.
b. Select the Reset Port option. A Message message box displays,
indicating a link reset operation will occur.
c. Click OK. The port resets.
12. Notify the customer the test is complete and the attached device
can be set online.
External Loopback
Test (Management
Server)
To perform an external loopback test at the management server
(Intrepid 6064 Element Manager application):
1. Notify the customer that a disruptive external loopback test is to
be performed and the attached device must be disconnected.
NOTE: At the start of the loopback test, the port or port card can be
online, offline, blocked, or unblocked.