FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)
5
5-2
Intrepid® 6064 Director Installation and Service Manual
Removal and Replacement Procedures (RRPs)
Procedural Notes
NOTE: The screens in this manual may not match the screens on your server
and workstation. The title bars have been removed and the fields may
contain data that does not match the data seen on your system.
The following procedural notes are referenced as applicable. The
notes do not necessarily apply to all procedures in the chapter.
1. Before performing a FRU repair, read the removal and
replacement procedures for that FRU carefully and thoroughly to
familiarize yourself with the procedures and reduce the
possibility of problems or customer down time.
2. Follow all electrostatic discharge (ESD) procedures, DANGER
and CAUTION statements, and statements listed in the preface of
this manual.
3. After completing the steps of a detailed procedure that is
referenced from another procedure, return to the initial
(referencing) procedure and continue to the next step of that
procedure.
4. After completing a replacement procedure, clear the event code
reporting the failure and the event code reporting the recovery
from the Event Log (at the management server or SANpilot
interface), and extinguish the amber system error light- emitting
diode (LED) at the director front bezel.
Removing and Replacing FRUs
This section describes procedures to remove and replace director
FRUs, along with a list of tools required to perform each procedure.
In addition, the section provides:
• ESD information
• A list of concurrent FRUs. Concurrent FRUs can be removed and
replaced while the director is powered on and operational.
• A list of nonconcurrent FRUs. Nonconcurrent FRUs can only be
removed and replaced after the director is powered off.
See Chapter 6, Illustrated Parts Breakdown for FRU locations and part
numbers.