FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)
5
5-10
Intrepid® 6064 Director Installation and Service Manual
Removal and Replacement Procedures (RRPs)
— Do not reinstall the failed replacement CTP2 card because this
can corrupt director firmware. Obtain a new CTP2 card and
perform this replacement procedure.
6. Verify that synchronization is complete by viewing the Event log.
7. Connect the Ethernet LAN cable to the RJ-45 connector on the
faceplate of the replacement CTP2 card.
8. Disconnect the ESD wrist strap from the director chassis and your
wrist.
9. Inspect the CTP2 card to ensure the amber LED is extinguished. If
the amber LED is illuminated, go to MAP 0000: Start MAP on
page 3-9 to isolate the problem.
10. At the management server or at a web browser connected to the
SANpilot interface, inspect the Event Log. Ensure the following
event codes appear in the log:
— 410 - CTP2 card reset.
— 416 - Backup CTP2 installed.
— 422 - CTP2 firmware synchronization complete (only if the
firmware versions on the two CTP2 cards are different).
If the event codes do not appear in the log, go to MAP 0000: Start
MAP on page 3-9 to isolate the problem.
11. Perform one of the following to verify CTP2 card operation:
— If at the management server, open the Hardware View and
observe the CTP2 card graphic to ensure no alert symbols
appear that indicate a failure (yellow triangle or red diamond).
If a problem is indicated, go to MAP 0000: Start MAP on
page 3-9 to isolate the problem.
— If at a web browser connected to the SANpilot interface, open
the Switch tab at the View panel and ensure no amber LEDs
illuminate that indicate a CTP2 card failure. If a problem is
indicated, go to MAP 0000: Start MAP on page 3-9 to isolate
the problem.
12. Perform the data collection procedure (Collecting Maintenance
Data on page 4-39).