FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)

5
RRP: Port Module Card (UPM and XPM)
5-11
Removal and Replacement Procedures (RRPs)
13. If the customer requests the replacement CTP2 card be set as the
active card, perform a FRU switchover. At the Hardware View,
right-click the graphic representing the replacement card to open
a menu, then select Switchover.
14. Perform one of the following to clear the system error (ERR) LED:
If at the management server, open the Hardware View and:
a. Right-click the front panel bezel graphic (away from a
FRU) to open a menu.
b. Click the Clear System Error Light menu selection.
If at a web browser connected to the SANpilot interface:
a. Click the Switch tab at the Operations panel. The Operations
panel opens with the Switch page displayed.
b. Click the Sys Err Light tab. The Switch page displays with
the Sys Err Light tab selected. A System Error Light is ON
message displays on the page.
c. Click Clear Light.
15. If necessary, close and lock the equipment cabinet door.
RRP: Port Module Card (UPM and XPM)
Use the following procedures to remove or replace a UPM or XPM
card. A list of tools required is provided.
Tools Required The following tools are required to perform these procedures.
Door key with 5/16-inch socket (provided with the FC-512
Fabricenter equipment cabinet).
ESD grounding cable and wrist strap.
Torque tool and hex adapter (provided with the director).
Fiber-optic protective plugs (provided with the director).
Protective caps (provided with fiber-optic jumper cables).
Fiber-optic cleaning kit.
Removal To remove a UPM or XPM card: