FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)

5
5-16
Intrepid® 6064 Director Installation and Service Manual
Removal and Replacement Procedures (RRPs)
501 - Port card has been recognized.
If an event code 501 does not appear in the log, go to MAP 0000:
Start MAP on page 3-9 to isolate the problem.
9. At the Hardware View, double-click the graphic representing the
replacement card to open the Port Card View. At the Port Card
View:
a. Ensure no alert symbols appear that indicate a failure
(yellow triangle or red diamond).
b. Verify port card information (FRU name, position, and state) is
correct.
If a problem is indicated, go to MAP 0000: Start MAP on page 3-9
to isolate the problem.
10. Restore communication to the replacement port card and set the
card online as directed by the customer (Blocking and Unblocking
Ports on page 4-46). Inform the customer the port card is available
for use.
11. Perform the data collection procedure (Collecting Maintenance
Data on page 4-39).
12. Perform one of the following to clear the system error (ERR) LED:
If at the management server, open the Hardware View and:
a. Right-click the front panel bezel graphic (away from a
FRU) to open a menu.
b. Click the Clear System Error Light menu selection.
If at a web browser connected to the SANpilot interface:
a. Click the Switch tab at the Operations panel. The Operations
panel opens with the Switch page displayed.
b. Click the Sys Err Light tab. The Switch page displays with
the Sys Err Light tab selected. A System Error Light is ON
message displays on the page.
c. Click Clear Light.
13. If necessary, close and lock the equipment cabinet door.