FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)

5
5-20
Intrepid® 6064 Director Installation and Service Manual
Removal and Replacement Procedures (RRPs)
9. Restore communication to the port with the replacement
transceiver as directed by the customer (Blocking and Unblocking
Ports on page 4-46). Inform the customer the port is available for use.
10. Perform one of the following to clear the system error (ERR) LED:
If at the management server, open the Hardware View and:
a. Right-click the front panel bezel graphic (away from a
FRU) to open a menu.
b. Click the Clear System Error Light menu selection.
If at a web browser connected to the SANpilot interface:
a. Click the Switch tab at the Operations panel. The Operations
panel opens with the Switch page displayed.
b. Click the Sys Err Light tab. The Switch page displays with
the Sys Err Light tab selected. A System Error Light is ON
message displays on the page.
c. Click Clear Light.
11. If necessary, close and lock the equipment cabinet door.
RRP: Filler Blank (UPM and XPM)
Use the following procedures to remove or replace a UPM or XPM
filler blank. Filler blanks cover and protect unused port card slots in the
director chassis. A list of tools required is provided.
Tools Required The following tools are required to perform these procedures.
Door key with 5/16-inch socket (provided with the FC-512
Fabricenter equipment cabinet).
Torque tool and hex adapter (provided with the director).
Removal To remove a filler blank:
1. If the director is installed in a stand-alone configuration, go
to step 2. If the director is rack-mounted, perform one of the
following:
If the director is installed in a McDATA-supplied FC-512
Fabricenter equipment cabinet, insert the 5/16" door tool into
the socket hole at the right top of the front door. Turn the tool
counter-clockwise to unlock and open the door.