FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)

A
A-8
Intrepid® 6064 Director Installation and Service Manual
Messages
Message Cannot run diagnostics while a device is logged-in to the port.
Description Port diagnostics (internal loopback test) cannot be performed on a
port while an attached Fibre Channel device is logged in.
Action Log out the device and run the diagnostic test again.
Message Cannot save IPL configuration file while active=save is enabled.
Description The user cannot save the IPL file while the active=save property is
set.
Action The FICON management server property, active=save, must be
disabled for EFCM to save the IPL file.
Message Cannot save port configuration.
Description Port configuration cannot be saved. The link is down or busy.
Action Retry the operation later. If the condition persists, contact support
personnel and report the problem.
Message Cannot save SNMP configuration.
Description SNMP configuration cannot be saved. The link is down or busy.
Action Retry the operation later. If the condition persists, contact support
personnel and report the problem.
Message: Cannot set all ports to 1 Gb/sec due to port speed restriction on
some ports.
Description: Displays if all ports are set to 1 Gb/sec through the Configure Ports
dialog box and some ports do not support speed configuration.
Action: Replace ports that do not support speed configuration (FPM cards)
with those that support more than one speed configuration (UPM
cards).