FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)
A
Intrepid 6064 Element Manager Messages
A-13
Messages
Message Device applications should be terminated before starting
diagnostics. Press NEXT to continue.
Description Device application is not terminated.
Action Terminate device application before running port diagnostics.
Message [device WWN] cannot be removed from the switch membership list
while participating in switch binding. The device must be isolated
from the switch, or switch binding deactivated before it can be
removed.
Description A user attempted to remove a device WWN from the director or
switch membership list (SANtegrity binding feature) with switch
binding enabled.
Action Disconnect the device by blocking the director or switch port and
setting the director or switch offline, or disable switch binding
through the Switch Binding Change State dialog box before removing
devices from the membership list.
Message Director clock alert mode must be cleared before enabling period
synchronization.
Description Clock alert mode is enabled through the Configure FICON
Management Server dialog box and user is attempting to enable
Periodic Date/Time Synchronization through the Configure Date and Time
dialog box.
Action Disable clock alert mode through the Configure FICON Management
Server dialog box.
Message Disabling Insistent Domain ID will disable fabric binding. Do you
want to continue?
Description Fabric binding is enabled through the SAN management application
and a user attempted to disable the Insistent Domain ID parameter at
the Configure Switch Parameters dialog box.
Action Click Yes to continue and disable fabric binding.