FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)

B
CTP/CTP2 Card Events (400 through 499)
B-49
Event Code Tables
Event Code: 451
Message: Switch speed incompatibility detected.
Severity: Informational.
Explanation: This event occurs when the configured director speed saved in NVRAM conflicts with the speed capability of the
director. This event may occur when backup CTP hardware running an early version of software (below version
1.3) is improperly synchronized with a CTP operating at greater than 1 Gbps.
Action: None. Director speed configuration and port speed configuration data will be set to a level that is compatible with
the CTP, and the CTP will automatically be IPLed.
Event Data: None.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔
Event Code: 452
Message: Backup CTP incompatible with configured system settings.
Severity: Informational.
Explanation: This event occurs when the backup CTP is failed as a result of being incompatible with current system settings.
Normally this event will be generated following a hot-plug or power-on reset. (This event usually occurs when a
CTP is installed into a system operating at a director speed that is not supported by the CTP.) This event should
be followed by a 414 event.
Action: Replace the backup CTP with a version of hardware capable of supporting the user-configured settings, or adjust
the user settings to be compatible with the backup CTP and reseat the backup CTP.
Event Data: None.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔