FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)

B
Port Card (UPM and XPM) Events (500 through 599)
B-53
Event Code Tables
Event Code: 503
Message: Port card hot-removal completed.
Severity: Informational.
Explanation: A UPM was removed with the director powered on and operational.
Action: No action required.
Event Data: Byte 0 = UPM slot position
Bytes 4 - 7 = elapsed millisecond tick count.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔
Event Code: 504
Message: Port module failure.
Severity: Major.
Explanation: The indicated UPM failed.
Action: Replace the indicated UPM with a functional UPM of the same type. Perform the data collection procedure and
return the CD and faulty card to McDATA support personnel.
Event Data: Byte 0 = UPM slot position
Byte 1 = engineering reason code.
Bytes 4 - 7 = elapsed millisecond tick count.
Bytes 8 - 11 = reason code specific data.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔✔✔✔✔