FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)
B
B-54
Intrepid® 6064 Director Installation and Service Manual
Event Code Tables
Event Code: 505
Message: Port module revision not supported.
Severity: Minor.
Explanation: The indicated UPM is not recognized and the four ports appear uninstalled to the director firmware.
Action: Ensure the director model supports the operating firmware version. If the firmware version is supported, replace
the UPM with a functional card. Perform the data collection procedure and return the CD and faulty card to
McDATA support personnel.
Event Data: Byte 0 = UPM slot position).
Bytes 4 - 7 = elapsed millisecond tick count.
Bytes 8 and 9 = detected module identifier.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔
Event Code: 506
Message: Fibre Channel port failure.
Severity: Major.
Explanation: A Fibre channel port on a UPM failed. The amber LED corresponding to the port illuminates to indicate the
failure. Other ports remain operational if their LEDs are extinguished.
Action: Replace the indicated UPM with a functional UPM of the same type. Perform the data collection procedure and
return the CD and faulty card to McDATA support personnel.
Event Data: Byte 0 = port number. Bytes 17 and 18 = transmitter technology.
Byte 1 = engineering reason code. Byte 19 = distance capabilities.
Bytes 4 - 7 = elapsed millisecond tick count. Byte 20 = supported transmission media.
Bytes 8 - 11 = reason code specific. Bytes 21 and 22 = speed capability and configuration.
Byte 16 = connector type.