FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)
B
Port Card (UPM and XPM) Events (500 through 599)
B-55
Event Code Tables
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔✔✔✔✔
Event Code: 507
Message: Loopback diagnostics port failure.
Severity: Informational.
Explanation: A loopback diagnostic test detected a Fibre Channel port failure.
Action: No action required. An event code 506 is generated if this diagnostic failure results in a hard port failure.
Event Data: Byte 0 = port number.
Byte 1 = engineering reason code.
Bytes 4 - 7 = elapsed millisecond tick count.
Bytes 8 - 11 = reason code specific.
Byte 12 = test type.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔