FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)
B
Port Card (UPM and XPM) Events (500 through 599)
B-59
Event Code Tables
Event Code: 514
Message: SFP/XFP optical transceiver failure.
Severity: Major.
Explanation: An SFP or XFP optical transceiver failed. The amber LED corresponding to the port illuminates to indicate the
failure. Other ports remain operational if their LEDs are extinguished.
Action: Replace the failed transceiver with a functional transceiver of the same type.
Event Data: Byte 0 = port number.
Byte 2 = type of optics: Bit 1 = SFP; Bit 2 = XFP.
Bytes 4 - 7 = elapsed millisecond tick count.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔✔✔✔✔
Event Code: 515
Message: SFP/XFP optics digital diagnostics warning threshold exceeded.
Severity: Minor.
Explanation: A digital diagnostics warning threshold is exceeded. If warning condition persists, additional 515 events are
generated.
Action: Replace the failed transceiver with a functional transceiver of the same type.
Event Data: Byte 0 = port number.
Byte 2 = type of optics: Bit 1 = SFP; Bit 2 = XFP.
Bytes 4 - 7 = elapsed millisecond tick count.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔