FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)

B
Port Card (UPM and XPM) Events (500 through 599)
B-61
Event Code Tables
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔
Event Code: 570
Message: Link recovery action.
Severity: Informational.
Explanation: Link recovery was performed by E/OS firmware to recover an unsuitable link.
Action: Check port statistics invalid transmission words and CRC errors. Verify that the attached device is honoring the
buffer-to-buffer flow control protocol as described in the FC-FS standard.
Event Data: Byte 0 = port number.
Byte 1 = link recovery reason code.
Bytes 4 - 7 = elapsed millisecond tick count.
Distribution: Director Management Server Host