FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)

B
B-64
Intrepid® 6064 Director Installation and Service Manual
Event Code Tables
Event Code: 585
Message: Primitive sequence timeout.
Severity: Major.
Explanation: An attached OSI or FICON server recognized either a link reset (LR) protocol timeout or a timeout while waiting
for the appropriate response (while in a NOS receive state and after NOS was not longer recognized).
Action: A LIR is generated and sent to the attached server using the reporting procedure defined in T11/99-017v0 (OSI)
or the FICON architecture document (FICON). If fault isolation at the server does not detect a failure, the problem
may be due to a port failure. See MAP 0000: Start MAP on page 3-9 for instructions.
Event Data: Refer to the T11/99-017v0 or FICON architecture document for the specific link incident record format.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Event Code: 586
Message: Invalid primitive sequence received for current link state.
Severity: Major.
Explanation: An attached OSI or FICON server recognized either a link reset (LR) or a link-reset response (LRR) sequence
while in the wait-for-online sequence (OLS) state.
Action: A LIR is generated and sent to the attached server using the reporting procedure defined in T11/99-017v0 (OSI)
or the FICON architecture document (FICON). If fault isolation at the server does not detect a failure, the problem
may be due to a port failure. See MAP 0000: Start MAP on page 3-9 for instructions.
Event Data: Refer to the T11/99-017v0 or FICON architecture document for the specific link incident record format.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident