FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)
B
B-66
Intrepid® 6064 Director Installation and Service Manual
Event Code Tables
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔
Event Code: 602
Message: SBAR anomaly detected.
Severity: Informational.
Explanation: Director operational firmware detected a deviation in the normal operating mode or operating status of the
indicated SBAR.
Action: No action required. An event code 604 is generated if the SBAR fails.
Event Data: Byte 0 = SBAR slot position. Byte 12 = detecting port.
Byte 1 = anomaly reason code. Byte 13 = connected port.
Bytes 4 - 7 = elapsed millisecond tick count. Byte 14 = participating SBAR.
Bytes 8 and 9 = high-availability error callout #1. Bytes 16 and 17 = high-availability error callout #3.
Bytes 10 and 11 = high-availability error callout #2. Bytes 18 and 19 = high-availability error callout #4.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔