FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)

B
B-68
Intrepid® 6064 Director Installation and Service Manual
Event Code Tables
Event Code: 605
Message: SBAR revision not supported.
Severity: Minor.
Explanation: The indicated SBAR is not recognized and appears uninstalled to the director firmware.
Action: Ensure the director model supports the operating firmware version. If the firmware version is supported, replace
the SBAR with a functional assembly. Perform the data collection procedure and return the CD and faulty
assembly to McDATA support personnel.
Event Data: Byte 0 = SBAR slot position.
Bytes 4 - 7 = elapsed millisecond tick count.
Bytes 8 and 9 = detected module identifier.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔
Event Code: 607
Message: Director contains no operational SBARs.
Severity: Severe.
Explanation: The director firmware does not recognize an installed SBAR.
Action: Install at least one functional SBAR and power-on reset (POR) the director.
Event Data: Bytes 4 - 7 = elapsed millisecond tick count.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔✔✔✔