FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks Director Release Notes (AA-RTDVH-TE, August 2005)

Firmware 06.02.00-22 provides support for second-generation Edge Switch 2/12 and
Edge Switch 2/24 switches. This is the minimum M-Series rmware supported on the
second-generation Edge Switch 2 /12 and Edge Switch 2/24.
For customers who want to add a second-generation switch to their existing SAN, but
are not ready to upgrade their SAN from 5.x to 06.02.00, there is a downgrade
rmware version for each of these edge switches which provides compatibility with a
SAN running 05.02.00.
Firmware 05.03.01-01 is available for the Edge Switch 2/24, and rmware
05.05.01-01isavailablefortheEdgeSwitch2/12.Theseversionsareinstalledonlyon
the Edge Switch 2/24 and Edge Switch 2/12, and only when these switches are plac ed
in a M-Series SAN running 05.02.00 rmware. A copy of these versions of rmware,
are contained on the HP StorageWorks edge switch documentation and rmware CD
(Part Number 524-000001-005).
Reinstall
ing feature licenses
Feature li
censes (or keys) must be reinstalled after performing a factory reset on a
director t
o regain use of the licensed features (e.g., SANtegrit y B inding ).
Disconnecting the null modem cable
Always log out and disconnect the null modem cable from the serial maintenance port
when not in use or when the switch i s reset.
CTP contr
ols port l ights
Port lights on the edge switch and director products are controlled by the CTP
functionality. Certai n activities such as rmware updates, IPLing the CTP, or switching
over to the backup CTP (director) can cause these port lights to extinguish momentarily
until control is reasserted by the CTP. The actual Fibre Channel trafcisnotaffected
during
these times.
Ethernet switch suppor t
With rmware 06.00.00 and later, customers can now connect the management port on
edge switches and directors to Ethernet switches or hubs. Prior to rmware 06.00.00,
only connections to Ethernet hubs were qualied and supported.
Full Volatility
Full Volatility is an optional feature of rmware 06.00.00 and later that is enabled
wit
h a feature key. The Full Volatility feature is designed to support high-security
environments, which require that customer data not be retained by the edge switch or
director after power off.
Director release notes
19