FW V06.XX/HAFM SW V08.02.00 HP StorageWorks CLI Reference Guide for Directors and Edge Switches Reference Guide (AA-RQ7AE-TE, July 2004)

CLI Commands
116 CLI Reference Guide for Directors and Edge Switches
Output Example
The output from the config.switch.show command displays as follows.
BB Credit: 2
R_A_TOV: 20
E_D_TOV: 4
Preferred Domain Id: 1
Switch Priority: Principal
Speed: 2 Gb/sec
Rerouting Delay: Enabled
Interop Mode: Open Fabric 1.0
Insistent Domain Id: Disabled
Domain RSCN: Enabled
Zoning RSCN: Disabled
Limited Fabric RSCN: Disabled
Speed The switch speed. (This parliamentary is not valid for the
Edge Switch 2/24.)
Rerouting
Delay
The rerouting delay that ensures that frames are delivered
in order through the fabric to their destination.
Values are Enabled or Disabled.
Interop Mode Interoperability mode for the switch.
Insistent
Domain Id
When enabled, ensures that the embedded firmware cannot
change a switch's preferred domain ID.
Domain RSCN When enabled, allows domain RSCNs to be sent to
registered members of the fabric
Zoning RSCN When enabled, allows zoning RSCNs to be sent to
registered members of the fabric
Limited Fabric
RSCN
When enabled, fabric RSCNs are suppressed after an IPL.