FW V06.XX/HAFM SW V08.02.00 HP StorageWorks CLI Reference Guide for Directors and Edge Switches Reference Guide (AA-RQ7AE-TE, July 2004)

perf.link
161CLI Reference Guide for Directors and Edge Switches
Output Example
The output from the perf.link command displays as follows.
Port 2
Statistic Count
----------- ----------
OLS In 753452
OLS Out 351269
Reset In 2953184
Reset Out 1842953
Link Flrs 2953184
Sync Losses 1842953
Sig Losses 35246
Reset In The number of link resets initiated by the attached
N_Port.
Reset Out The number of link resets initiated by this director or
edge switch.
LIPS In The number of LIPS generated on this switch loop
port.
LIPS Out The number of times the port has detected a link
error resulting from an invalid link state transition or
timeout.
Link Flrs The number of times the port has detected a link
error resulting from an invalid link state transition or
timeout.
Sync Losses The number of times the port has detected a loss of
synchronization timeout while not in an offline or
LF2 state.
Sig Losses The number of times the port has detected a loss of
signal while not in an offline or LF2 state.