Description of Summed Sets
Some of the threshold alerts consist of groups of related items called
Summed Sets. When any of the items in the summed set are encountered, the total
value of the summed set counter is incremented. The items that make up the
summed sets are:
Physical Link Errors Summed Set
— Link Failures
— Sync Losses
— Signal Losses
— Protocol Errors
— Invalid Tx Words
— CRC Errors
—Frames Too Short
— Delimiter Errors
■ Link Sequence Counts Summed Set
— Link Resets Received
— Link Reset Sent
— OLS Received
—OLS Sent
■ Logical Link Errors Summed Set
— Discarded Frames
— Address ID Errors
— Class 2 Busied Frames
— Class 2 Rejected Frames
— Class 3 Discarded Frames