FW V06.XX/HAFM SW V08.02.00 HP StorageWorks CLI Reference Guide for Directors and Edge Switches Reference Guide (AA-RQ7AE-TE, July 2004)

CLI Commands
188 CLI Reference Guide for Directors and Edge Switches
Syntax
setParams name increment interval
Purpose
This command sets the increment and interval times for a specified counter
threshold alert.
Note: An alert cannot be modified unless it is in the disabled state.
Parameters
This command has the following parameters:
Example
The meaning for each of these inputs can best be described using the following
example sentence:
If ports 0, 1, or 2 CRC Error counter increments more then 5 times within a period
of 30 minutes, send an alert. Where:
Port list = 0, 1, 2
CTA Counter = CRCErrors
Increment value= 5
perf.thresholdAlerts.counter.setParams
name The name of a counter threshold alert as
defined by the command
perf.thresholdAlerts.counter.addAlert” on
page 183.
increment This sets the number of times a counter must
increment during the interval period to trigger
the alert. Acceptable values are in the range
of 1 to 70,560.
interval This sets the interval time in minutes for the
alert. Acceptable values are in the range of 5