FW V06.XX/HAFM SW V08.02.00 HP StorageWorks CLI Reference Guide for Directors and Edge Switches Reference Guide (AA-RQ7AE-TE, July 2004)

show.frus
217CLI Reference Guide for Directors and Edge Switches
Syntax
frus
Purpose
This command displays information about all FRUs.
Parameters
This command has no parameters.
Command Example
Root> show frus
Output
The FRU information is displayed as a table that includes the following
properties:
show.frus
FRU The FRU name. This property may show Unknown or
Not Installed if the FRU is not installed.
Position The relative position of the FRU, that is, its slot.
State The state of the FRU. Values are:
Active—the current module is active.
Backup—this module is not currently being used, but
it is available for immediate failover.
Failed—the current module is failed.
Serial Num The serial number of the FRU. (This field is blank for the
power supply modules of the Edge Switch 2/24.)
Part Num The part number of the FRU.
Beaconing The beaconing state of the FRU (on or off).
Pwr On Hrs The power-on hours value for the FRU.