FW V06.XX/HAFM SW V08.02.00 HP StorageWorks CLI Reference Guide for Directors and Edge Switches Reference Guide (AA-RQ7AE-TE, July 2004)

show.port.exit
235CLI Reference Guide for Directors and Edge Switches
Output
The output from show.port.exit includes the following parameters:
Command and Output Examples
The following examples show the output returned by the three methods of
specifying the show.port.exit command.
Output with single values for both parameters
Root> show port exit 21 10
Exit Port: 45
Output with destDomainId set to all
Root> show port exit all 15
Destination Domain Exit Port
------------------ ----------------
1 23
2 No Domain
3 23
31 No Domain
Destination
Domain
The destination domain ID to which a preferred
path has been configured. This is displayed only
if the destination domain parameter is set to
all.
Source Port The source port for which a preferred path to the
specified destination domain ID is specified.
This is displayed only if the source port
parameter is set to all.
Exit Port This is the actual exit port being used for the
given path. The value No Domain displays
when the destination domain doesn't exist in the
fabric. The value No Source displays when
the source port is in an offline state. The value
Fabric Building displays when the fabric
is still building.