FW V06.XX/HAFM SW V08.02.00 HP StorageWorks CLI Reference Guide for Directors and Edge Switches Reference Guide (AA-RQ7AE-TE, July 2004)

show.preferredPath.showPath
247CLI Reference Guide for Directors and Edge Switches
Syntax
showPath destDomainID sourcePort
Purpose
This command displays the specified Preferred Path configuration and the actual
path used by the system. The output shows both the exit port, as configured for the
Preferred Path feature, and the actual exit port currently being used for traffic.
Use all for one of the command’s parameters to display all configured and actual
exit ports for either the destination domain ID or the specified source Port. You
cannot specify all for both parameters. If the destination domain is set to all, all
paths from the specified source port are displayed. If the source port is set to all,
the output shows all source port paths to the specified domain.
Parameters
This command has the following parameters:
show.preferredPath.showPath
destDomainId Specifies the destination domain ID. Valid
domain IDs are in the range 1–31 or all,
which shows all paths to and from the source
port specified in the sourcePort parameter.
sourcePort Specifies the number of the source port. Valid
port numbers values are:
0–11 for the Edge Switch 2/12
0–15 for the Edge Switch 2/16
0-23 for the Edge Switch 2/24
0–31 for the Edge Switch 2/32
0–63 for the Director 2/64
0–127 and 132–143 for the Director 2/140
Or, you can specify all to show all paths to the
destination domain ID specified for the
destDomainId parameter.