FW V06.XX/HAFM SW V08.02.00 HP StorageWorks CLI Reference Guide for Directors and Edge Switches Reference Guide (AA-RQ7AE-TE, July 2004)

Error Messages
279CLI Reference Guide for Directors and Edge Switches
Error 91: E_Port Type
Configured
Ports cannot be
configured as E_Ports in
S/390 mode (FICON
management style in
HAFM).
Reconfigure the port as
either an F_Port or a
G_Port, and then
resubmit the command.
Error 92: Not Allowed
While Port Is Unblocked
The port must be blocked
to complete this request.
Block the port, and then
resubmit the command.
Error 93: Not Allowed
While FICON MS Is
Installed
This request cannot be
completed because
FICON Management
Server is installed.
This action is not
supported. No action
necessary.
Error 94: Invalid Feature
Combination
The requested features
cannot be installed at the
same time on one
director or edge switch.
Contact your sales
representative.
Error 99: Preferred
Domain ID Cannot Be
Zero
This switch cannot be
configured to have a
preferred domain ID
equal to zero (0).
Enter an integer in the
range 1–31 for the
preferred domain ID.
Error 101: Command
Not Supported on This
Product
This product does not
support the specified
command.
Information only
message: this operation is
not supported.
Error 102: Switch Not
Operational
The request cannot be
completed because the
switch is not operational.
Refer to the product
service manual, and
consult your service
representative.
Error 103: Port
Diagnostic In Progress
The request cannot be
completed because a port
diagnostic is running.
Wait for the diagnostic to
complete.
Error 104: System
Diagnostic In Progress
The request cannot be
completed because a
system diagnostic is
running.
Wait for the diagnostic to
complete.
Error 105: Max
Threshold Definitions
Reached
The maximum number of
total threshold alerts has
already been reached.
Remove a threshold alert
before adding the new
threshold alert. A total of
16 counter and
throughput threshold
alerts is allowed.
Table 6: CLI Error Messages (Continued)
Message Description Action