FW V06.XX/HAFM SW V08.02.00 HP StorageWorks CLI Reference Guide for Directors and Edge Switches Reference Guide (AA-RQ7AE-TE, July 2004)

Error Messages
281CLI Reference Guide for Directors and Edge Switches
Error 117: Ports Cannot
be Set at Higher Data
Rate than Switch Speed
The request cannot be
completed because the
requested port speed is
faster than the configured
switch speed.
The switch speed should
first be configured to
accommodate changes in
the configured port
speed. The ports cannot
operate at a faster rate
than the switch itself.
Update the switch speed
and resubmit the request.
For more information
about setting speeds, see
config.switch.speed” on
page 114 and
config.port.speed” on
page 60.
Error 118: Invalid Port
Speed
This request cannot be
completed because the
requested port speed is
not recognized for this
product.
Port speeds may be set to
1 Gbps or 2 Gbps.
Update the port speed
and resubmit the request.
Error 119: Switch Speed
Not 2 Gb/sec
This request cannot be
completed because the
switch speed has no been
set to 2 Gbps.
The switch speed must be
set to 2 Gbps in order to
accommodate a port
speed of 2 Gbps. Update
the switch speed and
resubmit the request.
Error 134: Invalid
Membership List
Generic message to
indicate a problem in
either the Switch Binding
or Fabric Binding
Membership List.
Be sure that the
membership list submitted
does not isolate a switch
already in the fabric. If
this is not the case, the
user needs to be aware of
all fabric security rules
and make sure that the
list submitted adheres
appropriately.
Table 6: CLI Error Messages (Continued)
Message Description Action