FW V06.XX/HAFM SW V08.02.00 HP StorageWorks CLI Reference Guide for Directors and Edge Switches Reference Guide (AA-RQ7AE-TE, July 2004)

Error Messages
285CLI Reference Guide for Directors and Edge Switches
Error 153: Feature Key
Not Installed
The request cannot be
completed because the
required feature key has
not been installed to the
firmware.
Contact your sales
representative.
Error 154: Invalid
Membership List WWN
The request cannot be
completed because the
WWN does not exist in
the switch binding
membership list.
Make sure that the WWN
deleted matches the
WWN in the Switch
Binding Membership List.
Make appropriate
changes and re-submit
the request.
Error 155: Cannot
Remove Active Member
From List
This member cannot be
removed from the fabric
security list because it is
currently logged in.
Fabric security rules
prohibit any device or
switch from being
isolated from the fabric
via a membership list
change. If it is truly the
intention of the user to
remove the device in
question from the
membership list, then
there are several
approaches to take. This
request may be
completed most
non-disruptively by
blocking the port (or
physically removing the
device from the managed
switch) to which this
device is attached and
resubmitting the request.
Error 156: Cannot
Complete while Switch is
Online and Fabric
Binding is Active
The switch must be offline
and fabric binding must
be inactive before this
feature can be disabled.
Deactivating this feature
can be disruptive to
fabric operations. Take
the switch offline and
deactivate fabric binding
before disabling this
feature.
Table 6: CLI Error Messages (Continued)
Message Description Action