FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Installation Guide (AA-RSNGD-TE, July 2004)

Overview
24 Director 2/64 Installation Guide
Build fabric protocol error—A protocol error is detected during the
process of forming the fabric.
No principal switch—No director in the fabric is capable of becoming
the principal switch.
No response from attached switch—After a fabric is created, each
director in the fabric periodically verifies operation of all attached
switches and directors. An ISL segments if a switch or director does not
respond to a verification request.
ELP retransmission failure timeout—A director that exhibits a
hardware failure or connectivity problem cannot transmit or receive Class
F frames. The director did not receive a response to multiple exchange
link protocol (ELP) frames, did not receive a fabric login (FLOGI) frame,
and cannot join an operational fabric.
Hardware Components
The Director provides a modular design that enables quick removal and
replacement of FRUs. The following sections define Director 2/64 main
components.
Front View
Figure 1 shows Director 2/64 components accessible from the front of the
Director. Component descriptions follow the figure.