FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Installation Guide (AA-RSNGD-TE, July 2004)
Overview
24 Director 2/64 Installation Guide
— Build fabric protocol error—A protocol error is detected during the
process of forming the fabric.
— No principal switch—No director in the fabric is capable of becoming
the principal switch.
— No response from attached switch—After a fabric is created, each
director in the fabric periodically verifies operation of all attached
switches and directors. An ISL segments if a switch or director does not
respond to a verification request.
— ELP retransmission failure timeout—A director that exhibits a
hardware failure or connectivity problem cannot transmit or receive Class
F frames. The director did not receive a response to multiple exchange
link protocol (ELP) frames, did not receive a fabric login (FLOGI) frame,
and cannot join an operational fabric.
Hardware Components
The Director provides a modular design that enables quick removal and
replacement of FRUs. The following sections define Director 2/64 main
components.
Front View
Figure 1 shows Director 2/64 components accessible from the front of the
Director. Component descriptions follow the figure.