FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Installation Guide (AA-RSNGD-TE, July 2004)
Installing and Configuring the Director
54 Director 2/64 Installation Guide
Figure 15: AC power connections
HP System/e and Industry-Standard 19-inch Rack Installation
To install the director in a HP system/e or industry-standard 19-in rack, complete
the procedures in the following sections:
■ Install the Anti-tip Feet on an HP System/e Rack, page 54
■ Install Mounting Bracket Hardware in the Rack, page 55
■ Prepare the Front and Rear Rack Columns, page 59
■ Prepare the Switch for Installation, page 60
■ Finalize the Rack-Mounting Procedure, page 61
■ Sliding Shelf Installation—For an HAFM Appliance only, page 64
■ Recommended Cable Management, page 67
Install the Anti-tip Feet on an HP System/e Rack
Use the following procedure to mount anti-tip feet on a HP system/e rack only, as
shown in Figure 16:
1. Place the anti-tip feet (1), provided in the HP system/e and industry-standard
19-in rack-mount kits on the front and rear of the rack base.
2. Secure the anti-tip feet (1) to the base of the rack (front and rear).
3. Lower the rack feet (2) until they touch the floor.