FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)

Diagnostics
104 Director 2/64 Service Manual
21
The IP address defining the director to the HAFM application is incorrect or
unknown and must be verified. A maintenance terminal (PC) and asynchronous
RS-232 null modem cable are required to verify the director’s IP address. The
tools are provided with the director or by service personnel. To verify the IP
address:
1. Remove the protective cap from the 9-pin maintenance port at the rear of the
director (a Phillips-tip screwdriver may be required). Connect one end of the
RS-232 null modem cable to the port.
2. Connect the other cable end to a 9-pin communication port (COM1 or
COM2) at the rear of the maintenance terminal PC.
3. Power on the maintenance terminal. After the PC powers on, the Windows
desktop displays.
4. Click Start > Programs > Accessories > Communications >
HyperTerminal. The Connection Description dialog box displays.
Note: The following steps describe inspecting the IP address using HyperTerminal serial
communication software.
5. Type 64 in the Name field and click OK. The Connect To dialog box
displays.
6. Ensure the Connect using field displays COM1 or COM2 (depending on the
serial communication port connection to the director), and click OK. The
COMn Properties dialog box displays (where n is 1 or 2).
7. Configure the Port Settings parameters as follows:
Bits per second-57600.
Data bits-8.
Parity-None.
Stop bits-1.
Flow control-Hardware.
When the parameters are set, click OK. The Director 2/64 HyperTerminal
window displays.