FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)

Diagnostics
118 Director 2/64 Service Manual
23
Inspect CTP2 card operational states at the Embedded Web Server interface.
Inspect the Status fields for both CTP2 cards.
Does the Status field display a Failed message for either CTP2 card?
NO YES
A CTP2 card failure is indicated. Go to step 7.
24
Inspect SBAR assembly operational states at the Embedded Web Server interface.
Inspect the Status fields for both assemblies.
Does the Status field display a Failed message for either SBAR assembly?
NO YES
An SBAR assembly failure is indicated. Go to step 9.
The director is operational. Exit MAP.
MAP 0600: UPM Card Failure and Link Incident Analysis
This MAP describes fault isolation for Universal Processing Module (UPM)
cards, shortwave laser small form factor pluggable (SFP) optical transceivers, and
longwave laser SFP optical transceivers; and for Fibre Channel link incidents.
Failure indicators include:
One or more amber LEDs on the UPM card illuminate.
One or more emulated amber LEDs on a UPM card graphic at the Hardware
View illuminate.
A blinking red and yellow diamond (failed FRU indicator) displays over a
UPM card graphic or a yellow triangle (attention indicator) displays at the
alert panel of the Hardware View.
An event code recorded at the Director 2/64 Event Log or the Embedded Web
Server Event Log.
A port operational state message or a Failed message associated with a
UPM card at the Embedded Web Server interface.
A link incident message recorded in the Link Incident Log or Port Properties
dialog box.