FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)
Diagnostics
119Director 2/64 Service Manual
1
Was an event code 080, 081, 504, 505, 506, 507, 512, 514, 800, 801, or 802
observed at the director Event Log (HAFM appliance) or at the Embedded Web
Server Event Log?
YES NO
↓ Go to step 3.
2
Was an event code 581, 582, 583, 584, 585, or 586 observed at the console of an
OSI or FICON server attached to the director reporting the problem?
YES NO
↓ Go to step 4.
3
Table 12 lists event codes, brief explanations of the codes, and associated steps
that describe fault isolation procedures.
Table 12: MAP 0600: Event Codes
Event Code Explanation Action
080 Unauthorized World-Wide Name. Go to step 18
081 Invalid attachment. Go to step 20
504 UPM card failure. Go to step 6
505 UPM card revision not supported. Go to step 44
506 Fibre Channel port failure. Go to step 6
507 Loopback diagnostics port failure. Go to step 14
512 SFP optical transceiver nonfatal error. Go to step 6
514 SFP optical transceiver failure. Go to step 6
581 Implicit incident. Go to step 37
582 Bit error threshold exceeded. Go to step 37
583 Loss of signal or loss of synchronization. Go to step 37
584 Not operational primitive sequence received. Go to step 37
585 Primitive sequence timeout. Go to step 37