FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)
Diagnostics
120 Director 2/64 Service Manual
4
Is fault isolation being performed at the director?
YES NO
↓ Fault isolation is being performed at the HAFM appliance or
Embedded Web Server interface. Go to step 8.
5
Inspect the faceplates of UPM cards at the front of the director. Each card has an
amber LED (at the top of the card) that illuminates if the card fails or if any Fibre
Channel port fails.
Each card also has a bank of amber and green LEDs above the ports. Each LED
pair is associated with a corresponding port (for example, the top LED pair is
associated with the top port). The amber LED illuminates and the green LED
extinguishes if the port fails.
Are an amber port LED and the amber LED at the top of the UPM card
illuminated but not blinking (beaconing)?
YES NO
↓ The director is operational, however a link incident or other problem
may have occurred. Perform fault isolation at the HAFM appliance.
Go to step 8.
586 Invalid primitive sequence received for current
link state.
Go to step 7
800 High temperature warning (UPM card thermal
sensor).
Go to step 7
801 Critically hot temperature warning (UPM card
thermal sensor).
Go to step 7
802 UPM card shutdown due to thermal violation. Go to step 7
Table 12: MAP 0600: Event Codes (Continued)
Event Code Explanation Action