FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)

Diagnostics
122 Director 2/64 Service Manual
7
A UPM card failed, and the card must be removed and replaced (“RRP: UPM
Card” on page 236).
This procedure is concurrent and can be performed while director power is on.
Verify location of the failed card (Figure 27 and Figure 28 on page 121). For
an OSI environment, Figure 27 nd Figure 28 show UPM card numbers (0
through15) and port numbers (00 through 63). For a FICON environment,
Figure 27 and Figure 28 show UPM card numbers (0 through 15), port
numbers (00 through 63), and bolded logical port addresses (hexadecimal 04
through 43).
Notify the customer that all ports on the defective card are to be blocked.
Ensure the customer’s system administrator quiesces Fibre Channel frame
traffic through any operational ports on the card and sets attached devices
offline.
Perform an external loopback test for all ports on the replacement card as part
of FRU removal and replacement.
Perform the data collection procedure as part of FRU removal and
replacement.
Did UPM card replacement solve the problem?
NO YES
The director is operational. Exit MAP.
Contact the next level of support. Exit MAP.
8
Is fault isolation being performed at the HAFM appliance?
YES NO
Fault isolation is being performed at the Embedded Web Server
interface. Go to step 42.