FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)
Diagnostics
123Director 2/64 Service Manual
9
Does a blinking red and yellow diamond (failed FRU indicator) display over a
UPM card graphic at the Hardware View or display adjacent to a Fibre Channel
port graphic at the Port Card View?
NO YES
↓ A port or UPM card failure is indicated. Go to step 6.
10
Did a Fibre Channel port or UPM card (all ports) fail a loopback test?
NO YES
↓ Go to step 14.
11
Does a yellow triangle (attention indicator) display over a UPM card graphic at
the Hardware View or display adjacent to a port graphic at the Port Card View?
YES NO
↓ Go to step 13.
12
Inspect the port state and LED status for all ports with an attention indicator.
1. At the Port Card View, double-click the port graphic with the attention
indicator. The Port Properties dialog box displays.
2. Inspect the Operational State field at the Port Properties dialog box, and the
emulated green and amber LEDs adjacent to the port at the Port Card View.
3. Table 13 lists LED and port operational state combinations and associated
MAP 0600 (or other) steps that describe fault isolation procedures.
Table 13: MAP 0600: Port Operational and LED States
Operational State Green LED Amber LED Action
Offline Off Off Go to step 16
Not Operational Off Off Go to step 16
Testing Off Blinking Internal loopback test in
process. Exit MAP.