FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)

Diagnostics
124 Director 2/64 Service Manual
13
A link incident may have occurred, but the LIN alerts option is not enabled for the
port and the attention indicator does not display.
At the Hardware View, click Logs > Link Incident Log. The Link Incident Log
displays. If a link incident occurred, the affected port number is listed with one of
the following messages.
Link interface incident-implicit incident.
Link interface incident-bit-error threshold exceeded.
Link failure-loss of signal or loss of synchronization.
Link failure-not-operational primitive sequence (NOS) received.
Link failure-primitive sequence timeout.
Link failure-invalid primitive sequence received for the current
link state.
Did one of the listed messages display in the Link Incident Log?
YES NO
The director is operational. Exit MAP.
Go to step 33.
Testing On Blinking External loopback test
in process. Exit MAP.
Beaconing Off or On Blinking Go to step 17
Invalid Attachment On Off Go to step 18
Link Reset Off Off Go to step 32
Link Incident Off Off Go to step 33
Segmented E_Port On Off Go to MAP 0700:
Fabric, ISL, and
Segmented Port
Problem Determination.
Table 13: MAP 0600: Port Operational and LED States (Continued)
Operational State Green LED Amber LED Action