FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)
Diagnostics
131Director 2/64 Service Manual
26
An SBAR assembly failed and must be removed and replaced (“RRP: Redundant
SBAR Assembly” on page 248).
■ This procedure is concurrent and can be performed while director power is on.
■ Perform the data collection procedure as part of FRU removal and
replacement.
Did SBAR assembly replacement solve the problem?
NO YES
↓ The director is operational. Exit MAP.
Contact the next level of support. Exit MAP.
27
Inspect and service the host bus adapters (HBAs), as necessary.
Did service of the HBAs solve the problem?
NO YES
↓ Exit MAP.
Contact the next level of support. Exit MAP.
28
A port connection is not allowed because of an Exchange Security Attribute
(ESA) feature mismatch. Switch binding parameters must be compatible for both
fabric elements.
1. At the Hardware View, click Configure > Switch Binding > Change State.
The Switch Binding - State Change dialog box displays, as shown in
Figure 30.
Figure 30: Switch Binding - State Change dialog box