FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)
Diagnostics
133Director 2/64 Service Manual
3. At the Membership List of <Fabric Name> section, update the membership
list for both elements to ensure interswitch compatibility, then click OK. The
fabric binding feature is consistently enabled for both directors or switches.
Did updating the fabric membership lists solve the problem?
NO YES
↓ The director is operational. Exit MAP.
Contact the next level of support. Exit MAP.
30
A port connection is not allowed because of a switch binding mismatch. Switch
membership lists must be compatible for both fabric elements.
1. At the Hardware View for each director or switch, click Configure > Switch
Binding > Edit Membership List. The Switch Binding - Membership List
dialog box displays, as shown in Figure 32.
Figure 32: Switch Binding - Membership List dialog box
2. Ensure the Switch Membership List is updated and correct for each director
or switch.
3. Click Activate for each director or switch. The switch binding feature is
consistently enabled for both directors or switches.