FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)

Diagnostics
135Director 2/64 Service Manual
Figure 33: Clear Link Incident Alert(s) dialog box
5. Make sure the This port (n) only option (where n is the port number) is
selected and click OK. The link incident clears.
6. Monitor port operation for approximately five minutes.
Did the link incident recur?
YES NO
The problem is transient and the Fibre Channel link and director are
operational. Exit MAP.
34
Inspect the fiber optic jumper cable attached to the port and ensure the cable is not
bent and connectors are not damaged. If the cable is bent or connectors are
damaged:
1. Notify the customer the port will be blocked. Ensure the customer’s system
administrator quiesces Fibre Channel frame traffic through the port and sets
the attached device offline.
2. Block the port (“Block a Port” on page 207).
3. Remove and replace the fiber optic jumper cable.
4. Unblock the port (“Unblock a Port” on page 209).
Was a corrective action performed?
YES NO
Go to step 36.
35
Monitor port operation for approximately five minutes.
Did the link incident recur?
YES NO
The Fibre Channel link and director are operational. Exit MAP.