FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)
Diagnostics
142 Director 2/64 Service Manual
3
Is fault isolation being performed at the HAFM appliance?
YES NO
↓ Fault isolation is being performed through the Embedded Web Server
interface. Go to step 26.
4
Does a yellow triangle (attention indicator) display over a UPM card graphic at
the Hardware View?
YES NO
↓ The problem is transient and the director-to-fabric element
connection is operational. Exit MAP.
060 Fabric controller unable to synchronize
databases.
Go to step 9
061 Fabric controller database invalid. Go to step 9
062 Maximum interswitch hop count exceeded. Go to step 10
063 Received link state record too large. Go to step 11
070 E_Port is segmented. Go to step 12
071 Director is isolated. Go to step 12
072 E_Port connected to unsupported switch. Go to step 13
140 Congestion detected on an ISL. Go to step 21
142 Low BB_Credit detected on an ISL. Go to step 26
150 Zone merge failure. Go to step 27
Table 16: MAP 0700: Event Codes (Continued)
Event Code Explanation Action