FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)

Diagnostics
146 Director 2/64 Service Manual
Did fabric reconfiguration solve the problem?
NO YES
The director and multi-switch fabric are operational. Exit MAP.
Contact the next level of support. Exit MAP.
12
A 070 event code indicates an E_Port detected an incompatibility with an attached
director and prevented the directors from forming a multi-switch fabric. A
segmented E_port cannot transmit Class 2 or Class 3 Fibre Channel traffic.
A 071 event code indicates the director is isolated from all directors in a
multi-switch fabric, and is accompanied by a 070 event code for each segmented
E_Port. The 071 event code is resolved when all 070 events are corrected.
Obtain supplementary event data for each 070 event code.
1. At the Hardware View, click Logs > Event Log. The Event Log displays.
2. Examine the first five bytes (0 through 4) of event data.
3. Byte 0 specifies the director port number (00 through 63) of the segmented
E_port. Byte 4 specifies the segmentation reason (Table 18).
13
As indicated by an event code 072, a director E_Port is connected to an
unsupported switch or fabric element.
Advise the customer of the problem and disconnect the interswitch link to the
unsupported switch. Exit MAP.
Table 18: MAP 0700: Byte 4, Segmentation Reasons
Byte 4 Segmentation Reason Action
01 Incompatible operating parameters. Go to step 14
02 Duplicate domain IDs. Go to step 15
03 Incompatible zoning configurations. Go to step 16
04 Build fabric protocol error. Go to step 17
05 No principal switch. Go to step 19
06 No response from attached switch. Go to step 20
07 ELP retransmission failure timeout. Go to step 21