FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)

Diagnostics
147Director 2/64 Service Manual
14
A director E_Port segmented because the error detect time out value (E_D_TOV)
or resource allocation time-out value (R_A_TOV) is incompatible with the
attached fabric element.
1. Contact HP customer support or engineering personnel to determine the
recommended E_D_TOV and R_A_TOV values for both directors.
2. Notify the customer that both directors will set offline. Ensure the system
administrator quiesces Fibre Channel frame traffic through the directors and
sets attached devices offline.
3. Set both directors offline (“Set Offline State” on page 206).
4. At the Hardware View for the first director reporting the problem, click
Configure > Operating Parameters > Fabric Parameters. The Configure
Fabric Parameters dialog box displays, as shown in Figure 29 on page 129.
5. Type the recommended E_D_TOV and R_A_TOV values, then click
Activate.
6. Repeat step 4 and step 5 at the Hardware View for the director attached to the
segmented E_Port (second director). Use the same E_D_TOV and R_A_TOV
values.
7. Set both directors online (“Set Online State” on page 205).
Did the operating parameter change solve the problem, and did both directors join
through the ISL to form a fabric?
NO YES
The directors, associated ISL, and multi-switch fabric are operational.
Exit MAP.
Contact the next level of support. Exit MAP.
15
A director E_Port segmented because two fabric elements had duplicate domain
IDs.
1. Work with the system administrator to determine the desired domain ID
(1 through 31 inclusive) for each director.
2. Notify the customer that both directors will set offline. Ensure the system
administrator quiesces Fibre Channel frame traffic through the directors and
sets attached devices offline.