FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)

Diagnostics
152 Director 2/64 Service Manual
4. At the Switch Priority field, select a switch priority (Principal, Never
Principal, or Default). The switch priority value designates the fabric’s
principal switch. The principal switch is assigned a priority of 1 and controls
the allocation and distribution of domain IDs for all fabric directors and
switches (including itself).
Principal is the highest priority setting, Default is the next highest, and
Never Principal is the lowest priority setting. The setting Never Principal
means that the switch is incapable of becoming a principal switch. If all
switches are set to Principal or Default, the switch with the highest priority
and the lowest WWN becomes the principal switch.
At least one switch in a multi-switch fabric must be set as Principal or
Default. If all switches are set to Never Principal, all ISLs segment and the
message “No Principal Switch” displays in the Reason field of the
Port Properties dialog box.
5. Set the director online (“Set Online State” on page 205).
Did the switch priority change solve the problem and did both directors join
through the ISL to form a fabric?
NO YES
The directors, associated ISL, and multi-switch fabric are operational.
Exit MAP.
Contact the next level of support. Exit MAP.
20
A director E_Port segmented (at an operational director) because a response to a
verification check indicates an attached director is not operational.
1. Perform the data collection procedure at the operational director and return
the backup CD to HP for analysis by third-level support personnel.
2. Go to “MAP 0000: Start MAP” on page 46 and perform fault isolation for the
failed director.
Exit MAP.