FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)
Repair Information
172 Director 2/64 Service Manual
Link Incident Off Off Yellow
Triangle
A link incident occurred on the
port. The alert symbol displays
at the Port Card View, Port List
View, and Hardware View.
Link Reset Off Off Yellow
Triangle
The director and attached
device are performing a link
reset operation to recover the
link connection. This is a
transient state that should not
persist.
No Light Off Off None No signal (light) is received by
the director port. This is a
normal condition when there is
no cable attached to the port or
when the attached device is
powered off.
Not
Operational
Off Off Yellow
Triangle
The director port is receiving the
not operational sequence
(NOS) from an attached device.
Port Failure Off On Red and
Yellow
Blinking
Diamond
The director port failed and
requires service.
Segmented
E_Port
On Off Yellow
Triangle
The E_Port is segmented,
preventing two connected
directors from joining and
forming a multi-switch fabric.
Testing Off
On
Blinking
Blinking
Yellow
Triangle
Yellow
Triangle
The port is performing an
internal loopback test.
The port is performing an
external loopback test.
Table 22: Port Operational States (Continued)
Port
State
Green
LED
Amber
LED
Alert
Symbol
Description