FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)
Repair Information
181Director 2/64 Service Manual
■ Threshold Alert—If a threshold alert exists for the port, an alert indicator
(yellow triangle) and the configured name for the alert appear.
03 ELP rejected by the
attached switch.
This director or switch transmitted an exchange link
protocol (ELP) frame that was rejected by the switch at the
other end of the ISL (Invalid Attachment only).
04 Incompatible switch
at the other end of the
ISL.
Interop mode for this switch is set to Open Fabric mode,
and the switch at the other end of the ISL is a switch
configured for Homogeneous Fabric mode.
05 External loopback
adapter connected to
the port.
A loopback plug is connected to the port, and there is no
diagnostic test running.
06 N_Port connection
not allowed on this
port.
The port type configuration does not match the actual port
use. Port is configured as an E_Port, but it attaches to a
node device.
07 Non-homogeneous
switch at other end of
the ISL.
The cable is connected to a non-homogeneous switch and
interop mode is set to homogeneous fabric mode.
08 ISL connection not
allowed on this port.
This port type configuration does not match the actual
port use (the port is configured as an F_Port, but it
attaches to a switch or director).
10 Port binding
violation–unauthorized
WWN.
The WWN entered to configure port binding is not valid,
or a nickname was used that is not configured through the
Element Manager for the attached device.
11 Unresponsive node
connected to port.
Possible causes are:
■ Hardware problem on switch or on a connected node
where ELP frames are not delivered, the response is
not received, or a fabric login (FLOGI) cannot be
received. There may be problems in switch SBAR.
■ Faulty or dirty cable connection.
■ Faulty host bus adapters that do not send out FLOGI
within reasonable time frame.